DataChart 2000 Series Specifications

 

DataChart® DC-2000 Series Specifications
All Data-Chart Products are
CE and UL Approved

Data-Chart 2000 Series
2, 4, 6 or 12 direct inputs

DOWNLOAD A BROCHURE

 

blue.gif (875 bytes) Operating blue.gif (875 bytes) Recording blue.gif (875 bytes) Display blue.gif (875 bytes) Features blue.gif (875 bytes) Power blue.gif (875 bytes) Environmental
blue.gif (875 bytes) Options  blue.gif (875 bytes) Dimensions  blue.gif (875 bytes)Local Distributor

Top of FrameOPERATING
Input Signals 
DC Voltage: Linear, Industrial square root, logarithmic ± 150mV, ± 1.25V, ± 2.5VAccuracy: 0.06%
± 12.5V and ± 25VAccuracy: 0.1%
DC Current: 4-20mA, 0 to 20mA and 0 to 50 mA.Accuracy: 0.15% using external 50 ohm  0.1% shunt
Dry ContactOpen = 0, Closed = 1 
External:Signals can be input via serial port (Modbus). 
Thermocouple  Resolution: 0.1°C, Cold Junction Reference: 0.5°C  (0 to 50°C) Thermocouple burnout detection.
Thermocouple Info.DataChart® Specifications
Type Accuracy °CAccuracy°FAccuracy
J* 0.1%J -101 to 1200°C ± 1.5°C-150 to 2190°F± 3.0°F
K**0.1% K -101 to 1372°C ± 1.5°C -150 to 2500°F± 3.0°F 
T**0.2%T -101 to 400°C± 1.5°C-150 to 750°F ± 3.0°F
E**0.11%E -101 to 1000°C± 1.5°C-150 to 1832°F± 3.0°F
R0.16%R -50 to 1768°C± 3.0°C-58 to 3200°F± 6.0°F
S0.17% S -50 to 1768°C± -3.0°C-58 to 3200°F± 6.0°F
0.22% B   0 to 1820°C ± 4.0°C 32 to 3300°F± 7.0°F
C0.13%C   0 to 2400°C ± 3.0°C  32 to 4350°F± 6.0°F
N**0.10%N -101 to 1300°C± 1.5°C-150 to 2372°F± 3.0°F
* (± 2.5°C   -210 to -100°C)    **(± 2.5°C    -270 to -100°C)

Top of Frame

RTD's : Base accuracy 0.2% or 0.5°C (1°F). Resolution 0.1°C  2 or 3 wire connection. Cable compensation to ± 50 Ohm Open and short circuit detection.
10 ohm Cu-70 to 170°C-94 to 338 °F
100 ohm Pt 385-220 to 850°C-364 to 1560 °F
100 ohm Pt 392-180 to 820°C-292 to 1500 °F
200 ohm Pt 385-220 to 400°C-364 to 750 °F
200 ohm Pt 392-180 to 400°C-292 to 750 °F
120 ohm Ni-70 to 300°C-94 to 570 °F
1000 ohm NI-60 to 209°C-76 to 408 °F
(DIN 43760)  
Input Resolution 0.0015% of full scale, 16 bit unless otherwise stated
Input Impedance> 10 Meg on 150mV, 1.25V and 2.5V ranges, >100 K on 5, 12.5, 25 Volt ranges.
Input Channels 2, 4, 6 or 12 direct
Max Input50 Vdc
CMNR >100db, 50/60 Hz
Measurement Rate Measures all direct input channels every 125 milliseconds (each channel 8 times/second independent of no. of channels).
Math Functions +, -, x, /, logarithms, totalization, powers, averages, timers, and custom equations.
EMC Compliance Meets or exceeds the requirements of EMC 89/336/EEC

Top of FrameRECORDING

Recording RatesSelectable from 8/sec. to 10 minutes
Data Format Proprietary binary format for data security.
Data Storage Data stored in non-volatile RAM and recorded automatically, or on demand, to on board removable media. Full media format and verify capability.
 Media MeasurementsCapacity
Removable3.5" Disk700,0001.44MB
Compact Flash50 millionUp to 2 GB
Internal 1 Mb RAM (Non-Volatile) or 2 Mb RAM (Non-Volatile)
File TypesData files, Alarm and Event files, Configuration files, Language files. Multiple files of different names on a single disk.
Top of FrameDISPLAY

Display Type Color CCFL backlit Active Matrix TFT Liquid Crystal Display (5.6 inch) with touchscreen control.
Resolution 320 x 240 pixels.
Display Type Mono CCFL backlit STN Liquid Crystal Display (5.0 inch) with touchscreen control.
Resolution 240 x 128 pixels.
Display Modes Graphics (Trending vertical or horizontal), Bar Graphs (vertical or horizontal), Digital Meters, Alphanumeric Alarm and Event Data or combinations on a split screen. Review trended data. Search by time, date or signal value.
Virtual Chart Speed Programmable from 0.5in/hr to 600in/hr or 10mm.hr to 15,000mm/hr. Chart speed is independent of storage rate.
Display Windows Time/Date, Graphics (Bars, Large Digital, Trends), Disk Status, Systems Status, Menu Button Bar, Unit Indentification,Alarms/Events.

Top of FrameFEATURES

Touch Screen   Touch sensitive screen with Button Bar for simple programming and easy operation.
Math Package  Algebraic equations (basic math, powers, roots, natural and base 10 logarithms, exponentiation), peak monitoring, differentials, true rolling averages, time averages, gated timing, conditionals (Boolean logic), totalization, logarithmic scaling. 12 Programmable constants.
Buffer   Internal 128k buffer (RAM) enables real time browsing of historic chart data independent of recorded data. Equivalent browse capability is approximately 560 pen inches. This represents about 5½ days for 4 pens at 1 inch/hour.
File Browse
  Any data file on disk can be browsed. File directory allows selection of different file names.
Disk Full Alarm   User can set disk full threshold. Disk errors and alarms can be routed to contact closure.
Trend direction   User selectable Horizontal or Vertical chart trending. "Pen" pointers for easy trace identification.

Top of FramePOWER

Power Requirements 100 to 240Vac, 50/60Hz or 125 to 300Vdc, 35VA max. Optional 24Vdc +/-15%.
Power Fail Protection Programmed parameters stored in non-volatile memory. Clock battery backed. Data retention time without power >12 months.Chart and alarm browse buffers stored in non-volatile memory.
Safety UL (3111-1) cUL (IEC1010-1) CE low voltage directive 73/23/EEC. Complies with EN 61010-1.

Top of FrameENVIRONMENTAL

Temperature 5°C to 40°C per UL3111-1/IEC1010-1 with disk drive. -10°C to 50°C with PCMCA drive or ZIPTM Drive.
Humidity
10% to 80% RH per UL3111-1/IEC1010-1.
Wash Down IP65 Front panel only.

Top of FrameOPTIONS

Alarm Contacts 3 or 6 isolated Form C, 3 amp @ 250Vac or 26 Vdc.
Solid State Relays
3 or 6, 0.5 amp @ 30Vdc.

Remote Inputs
3 isolated inputs, user selectable as dry contact or 5 to 12 Vdc (mech. relay), 12 to 24 Vdc (SS relay) activated.. Inputs share a common. Configurable for chart control, alarm acknowledge/reset, event markers, totalizer reset or logic input.
Communications
ESD protected RS232 with full hand shaking. Supports modem or isolated RS485 port. Protocol: MODBUS RTU, MODBUS ASCII or serial printer port. Ethernet: 10BaseT. Unit may be remotely configured.
Printer Port
Parallel printer port (25 pin D shell connector).


Top of Frame DIMENSIONS


click the image to enlarge

DataChart 2000 ] DataChart 1200 ] DC Message System ] Companion Software ]

 
Monarch Instrument
15 Columbia Drive  Amherst, New Hampshire  03031  USA  Tel: 603-883-3390   Fax: 603-886-3300
Last Updated 12/12/2007
Prices and Specifications subject to change without notice.  ©1996-2007 Monarch Instrument all rights reserved.

Terms of Use For Website