DataChart® Data Loggers: pH/Temperature
The pHTEMP101 shares all the characteristics of our other Compact Data Loggers. It will directly connect to many commonly used pH electrodes, and ORP electrodes.
Advanced options like RF communications, multi-parameter recording, and multi-channel packages are all supported by our award winning Windows compatible software. Our software offers complete configuration and control of any of our devices. Powerful graphing and simple communications make your information easy to archive, document and share with others.
|
|
pHTEMP101 Features
- Memory: 13,107 per channel
- Form Factor: C-1
- Battery Factor: 2
- Battery Life: 1 yr.
- Weight: 4 oz. (120 g)
DataChart Compact Data Logger Software for Windows for all loggers order IFC101 Interface Cable and Software (except for Micro Series which requires IFC102 Interface Cable and Software.)
Multi-graphing This feature allows the simultaneous viewing of data from multiple data loggers on the same graph.
Excel®, This feature copies the currently selected data to an Excel spreadsheet. This eliminates the need to export data, title data sets, etc.
Zoom Focus on data of interest with powerful zoom and drag tools. Extended Zoom in and Zoom out capability. Supports multiple zoom in and zoom out. Features Box Zoom, Vertical Zoom and Horizontal Zoom as well as point and click.
Scaling This feature is available to all Voltage, Current, Pulse and Event Recorders. The user can program his own scaling parameters into a data logger.
Multiple Download Software can download data from multiple units simultaneously using our multiplexer.
Calibration Date Software automatically stores the last calibration date within each data logger. This is useful for reminding the user when a new calibration is required.
- Download Data without Disrupting Operation Our software allows downloading of data without disturbing the ongoing operation of the data logger. In addition, downloading the data will not drain the battery.
- Calibration Wizard All DataChart Data Loggers can be calibrated through our software. A calibration Wizard is provided in the software to simplify the calibration procedure.
- Axes Control The axis can be completely controlled through software. This includes setting the ranges, labeling, color control, series and legend properties, etc.
- Cursor Allows user to select specific data point values for display.
- Annotation Specific data points on the graph may be annotated (labeled).
- Automatic Time Synchronization Automatically align data from different loggers on the same graph and synchronizes them in time.
- Statistics Complete statistics on specified area of graph. Includes min, max, average, standard deviation, etc.
- Data Table A data table is instantly present at all times and automatically exported to Excel with a single click of the mouse. Start and stop times as well as all other parameters are exported as well.
- Real Time This feature provides the user with the ability to operate any data logger in real time and view the data while it is being taken.
- Printing Software prints graphs, data table, print preview, etc.
- Save Software can save data in multiple formats including text, csv, DataChart format as well as a binary format which is unalterable.
|
pHTEMP101 Specifications
| TEMPERATURE |
|
pH |
|
| Measurement Range: |
-200 to +850 °C (0 to +5000 ohms) |
Measurement Range: |
0.00 to 14.00 pH (-1000 to +1000 mV) |
| Resolution: |
0.01°C (0.001 ohms) |
Resolution: |
0.01 pH (0.1 mV) |
| Calibrated Accuracy: |
±0.1°C @25 °C ambient (+/- 0.015 ohms) |
Calibrated Accuracy: |
±0.1 pH (±1 mV) |
| Input Connection: |
Removable screw terminal; 2, 3 or 4-wire interface for 100 ohm Pt. |
Input Connection: |
Female BNC jack |
| RTD Reading Interval: |
1 every 2 sec. to 1 every 12 hrs. |
Input Resistance: |
1012 ohms (typical) |
| Calibration: |
Digital, through software |
Data Format: |
Date and time stamped °C, °F, °K, °R, ohms, pH, V, mV, engr. units specified through software. |
| |
|
Time Accuracy: |
±1 minute/month (at 25 °C; RS232 cable not in use) |
| |
|
Operating Environment: |
-5 to +50 °C, 5 to 95% RH (non-condensing) |
|
ACCESSORIES
|
|
|
|
| Item No. |
Name |
Description |
Image |
|
| 5399-9934 |
IFC202 |
USB Interface Cable and Software for all loggers except Micro models |
|
 |
| 5399-9902 |
IFC102 |
Interface Cable and Software for Micro models |
 |
 |
| 5399-9903 |
IFC110 |
Interface Cable and Software for all loggers except Micro models |
 |
 |
| 5399-9904 |
RFEXT-KIT |
Total Transceiver Package for PC and Logger sites. |
 |
 |
| 5399-9905 |
RFEXT-REMOTE |
Transceiver and cables for Logger site. |
|
 |
| 5399-9906 |
RFEXT-BASE |
Transceiver for PC Site Only |
|
 |
| 5399-9907 |
RF EXT |
Spare Transceiver and cables for either site |
|
CALL |
| 5399-9930 |
USB-1 |
USB to RS232 Converter |
 |
 |
| 5399-9931 |
USB101 |
USB Kit includes USB-1 and IFC110 Cable |
|
 |
| 5399-9932 |
NET-1 |
Serial to Ethernet Converter |
|
 |
| 5399-9933 |
NET101 |
NET-1 package and IFC110 Cable |
|
 |
| 5399-9940 |
pH-1 |
Gen. Purpose Laboratory pH Electrode |
 |
 |
| 5399-9999 |
N.I.S.T.Cert |
NIST Certificate of Calibration. Priced per parameter/channel |
|
 |
BATTERIES
|
|
|
|
| Item No. |
Name |
Description |
Image |
|
| 5399-9910 |
CR1225 |
Coin Cell for Micro Series, 48 mAH |
|
|
| 5399-9911 |
LTC-3PN |
3.6 Volt, Lithium Battery, 350 mAH |
|
|
| 5399-9912 |
TL-2150 |
3.6 Volt, Lithium Battery, 1/2 AA, Axial Leads, 950 mAH |
|
|
| 5399-9913 |
LTC-7PN |
3.6 Volt, Lithium Battery, 750mAH |
|
|
| 5399-9914 |
U9VL-J |
9.0 Volt, Lithium Battery, 1200 mAH |
|
|
| 5399-9915 |
CR1632 |
Coin Cell for Micro Series for Extended Battery Life, 125 mAH |
|
|
| 5399-9916 |
SB-5700 |
High Temperature 150C, Lithium Battery 1/2 AA, 800mAH |
|
|
DataChart® Compact Data Logger Software
Requires an IBM compatible PC with:
- Pentium or higher processor
- Windows 95/98/NT/2000/XP
- 8 MB extended RAM
- Color VGA monitor
- 5MB disk space
- CD-ROM
- 9 pin male Serial Port
Download the most recent version of the DC Compact Data Logger Software for Windows.
Monarch Instrument 2.02.5 |
pH MODEL
|
|
|
|
|
| Item No. |
Name |
Description |
Image |
|
| 5399-0401 |
pHTEMP101 |
pH and Temperature Recorder |

|
 |
|
|
|