Monarch Instrument
15 Columbia Drive
Amherst, NH 03031
ph: (603) 883-3390
Fx: (603) 886-3300
|
DataChart® Data Loggers: State/Event/Pulse
All our state/event recorders are devices which sense input transitions or contact closures from external sources such as transducers and/or state initiators. STATE recorders time stamp when any change of state (+ and -) occurs.
EVENT recorders time stamp when predefined unidirectional change (+ or -) occurs. Memory is nonvolatile solid state. The device can be started and stoped directly from your PC and is fully supported by our graphical Windows® based software.
PULSE101 senses and records the number of pulses/contact closures that occur over the user defined period. Store user defined units such as gollons/min. as well as scale factors and offset values. Easily linearize and scale any transducer that provides a pulse or contact closure output.
|
|
STATE101 Features
 |
| Memory |
13,107 |
| Form Factor |
A-1 |
| Battery Factor |
1 |
| Battery Life |
1 yr. |
| Weight |
1 oz (30 g) |
|
STATE110 Features
 |
| Memory |
13,107 |
| Form Factor |
A-2 |
| Battery Factor |
1 |
| Battery Life |
10 yr. |
| Weight |
1 oz. (30 g) |
|
QUADSTATE Features
 |
| Memory |
52,484 state changes |
| Form Factor |
B |
| Battery Factor |
2 |
| Battery Life |
1 yr. |
| Weight |
13 oz. (370 g) |
|
OCTSTATE Features
 |
| Memory |
104,857 state changes |
| Form Factor |
B1 |
| Battery Factor |
2 |
| Battery Life |
1 yr. |
| Weight |
17 oz. (480 g) |
|
EVENT101 Features
 |
| Memory |
13,107 |
| Form Factor |
A-1 |
| Battery Factor |
1 |
| Battery Life |
1 yr. |
| Weight |
1 oz. (30 g) |
|
EVENT110 Features
 |
| Memory |
13,107 |
| Form Factor |
A-2 |
| Battery Factor |
1 |
| Battery Life |
10 yr. |
| Weight |
1 oz. (30 g) |
|
PULSE101 Features
 |
| Memory |
16,383 |
| Form Factor |
A-1 |
| Battery Factor |
1 |
| Battery Life |
1 yr. |
| Weight |
1 oz. (30 g) |
|
|
General State Specifications
| Input Connection: |
Removable screw terminal |
| Input Low: |
<0.4V |
| Input High: |
>2.7V |
| Input Range: |
0 to 30V |
| Input Impedance: |
>1 Kohm |
| Time Resolution: |
1 second (reading rate dependent) |
| Visual Indicator: |
LED flahses at selected reading rate |
| Engineering Units: |
Use may define units up to 10 characters in length. This value is stored in device. |
| Scale Factor: |
User may program any desired scaling factor from ±1.000E-31 to ±9.999E+31. The scaling factor is stored within the device. |
| Real Time Recording: |
When used with PC. |
| Reading Interval: |
1/second to 1 every 12 hours. |
| Replaceable Battery: |
1 year typical life at 25 °C |
| Data Format: |
Date and time stamped state changes (on/off). |
| Time Accuracy: |
+/-1 minute/month at 20 °C, no RS232 in use. |
| Computer Interface: |
PC serial or RS232C COM |
| Software: |
Windows 95/98/ME/NT/2000/XP compatible |
| Operating Environment: |
-40 to +80 °C, 5 to 96 RH non-condensing. |
General Event Specifications
| Input Connection: |
Removable screw terminal |
| Input Low: |
<0.4V |
| Input High: |
>2.7V |
| Input Range: |
0 to 30V |
| Input Impedance: |
>1 Kohm |
| Minimum Input Active (Low) Time: |
1 ms |
| Time Resolution: |
1 second (reading rate dependent) |
| Visual Indicator: |
LED flahses at selected reading rate |
| Engineering Units: |
Use may define units up to 10 characters in length. This value is stored in device. |
| Scale Factor: |
User may program any desired scaling factor from ±1.000E-31 to ±9.999E+31. The scaling factor is stored within the device. |
| Real Time Recording: |
When used with PC. |
| *Reading Interval: |
1/second to 1 every 12 hours. |
| Replaceable Battery: |
1 year typical life at 25 °C |
| Data Format: |
Date and time stamped state changes (true/false). |
| Time Accuracy: |
±1 minute/month at 20 °C, no RS232 in use. |
| *Device records one event per user reading interval. |
General Pulse Specifications
| Maximum Pulse Rate: |
100 per second (10 ms) |
| Minimum Pulse Width/Contact Closure Time: |
1 ms |
| Input Signal: |
TTL, Internal pull-up, +30 Volts max. |
| Input Connection: |
Removable Screw Terminal |
| Input Impedance: |
>1 Kohm |
| Start Time: |
Software programmable start time and date, up to six months in advance. |
| Real Time Recording: |
When used with a PC |
| Scale Factor: |
User may program any desired scaling factor from ±1.0000E-31 to ±9.9999E+31. The scaling factor is stored within the device. |
| Offset Value: |
Software Programmable to any value from ±1.0000E-31 to ±9.9999E+31. The factor is stored in the device. |
| Reading Interval: |
1/second to 1 every 12 hours. |
| Visual Indicator: |
LED flashes at reading rate. |
| Data Format: |
Date and time stamped, V, mV, µV, user defined engineering units. |
| Time Accuracy: |
±1 minute/month at 20 °C, no RS232 in use. |
| |
|
ACCESSORIES
|
|
|
|
| Item No. |
Name |
Description |
Image |
|
| 5399-9934 |
IFC202 |
USB Interface Cable and Software for all loggers except Micro models |
|
 |
| 5399-9902 |
IFC102 |
Interface Cable and Software for Micro models |
 |
 |
| 5399-9903 |
IFC110 |
Interface Cable and Software for all loggers except Micro models |
 |
 |
| 5399-9904 |
RFEXT-KIT |
Total Transceiver Package for PC and Logger sites. |
 |
 |
| 5399-9905 |
RFEXT-REMOTE |
Transceiver and cables for Logger site. |
|
 |
| 5399-9906 |
RFEXT-BASE |
Transceiver for PC Site Only |
|
 |
| 5399-9907 |
RF EXT |
Spare Transceiver and cables for either site |
|
CALL |
| 5399-9930 |
USB-1 |
USB to RS232 Converter |
 |
 |
| 5399-9931 |
USB101 |
USB Kit includes USB-1 and IFC110 Cable |
|
 |
| 5399-9932 |
NET-1 |
Serial to Ethernet Converter |
|
 |
| 5399-9933 |
NET101 |
NET-1 package and IFC110 Cable |
|
 |
| 5399-9940 |
pH-1 |
Gen. Purpose Laboratory pH Electrode |
 |
 |
| 5399-9999 |
N.I.S.T.Cert |
NIST Certificate of Calibration. Priced per parameter/channel |
|
 |
|
BATTERIES
|
|
|
|
| Item No. |
Name |
Description |
Image |
|
| 5399-9910 |
CR1225 |
Coin Cell for Micro Series, 48 mAH |
|
|
| 5399-9911 |
LTC-3PN |
3.6 Volt, Lithium Battery, 350 mAH |
|
|
| 5399-9912 |
TL-2150 |
3.6 Volt, Lithium Battery, 1/2 AA, Axial Leads, 950 mAH |
|
|
| 5399-9913 |
LTC-7PN |
3.6 Volt, Lithium Battery, 750mAH |
|
|
| 5399-9914 |
U9VL-J |
9.0 Volt, Lithium Battery, 1200 mAH |
|
|
| 5399-9915 |
CR1632 |
Coin Cell for Micro Series for Extended Battery Life, 125 mAH |
|
|
| 5399-9916 |
SB-5700 |
High Temperature 150C, Lithium Battery 1/2 AA, 800mAH |
|
|
|
DataChart® Compact Data Logger Software
Requires an IBM compatible PC with:
- Pentium or higher processor
- Windows 95/98/NT/2000/XP
- 8 MB extended RAM
- Color VGA monitor
- 5MB disk space
- CD-ROM
- 9 pin male Serial Port
Download the most recent version of the DC Compact Data Logger Software for Windows.
Monarch Instrument 2.02.5
|
| |
| STATE/EVENT/PULSE |
|
|
|
| Item No. |
Name |
Description |
Image |
|
| 5399-0707 |
State 101 |
State Recorder |
 |
 |
| 5399-0708 |
State 110 |
Similar to State 101 w/ 10 Yr Battery & Fast Data Retrieval. |
 |
 |
| 5399-0704 |
Quad State |
4 Channel State Recorder |
 |
 |
| 5399-0705 |
Oct State |
8 Channel State Recorder |
 |
 |
| 5399-0703 |
Event 101 |
Event Recorder |
 |
 |
| 5399-0706 |
Event 110 |
Similar to Event 101 w/ 10 Yr Battery & Fast Data Retrieval. |
 |
 |
| 5399-0701 |
Pulse 101 |
Pulse Recorder |
 |
 |
| |
|
|
|
|