Monarch Instrument
15 Columbia Drive
Amherst, NH 03031
ph: (603) 883-3390
Fx: (603) 886-3300
|
Track-It™ Data Loggers: DC Voltage and current
The Track-It™ DC Voltage and Current Data Loggers are two channel battery powered stand alone compact data loggers that record up to 32,000 samples each of DC Voltage or Current data. Units are available in 4 DC voltage ranges or for DC current. The unit is easily configured using the included Track-It™ Software. Simply plug the logger into an open USB port on your PC and the software automatically identifies the logger. Configure the unit to start and stop recording at a predetermined time and date or only when an alarm condition is sensed. The sample storage rate can be set from 1 sample every 2 seconds to 1 sample every 24 hours.
The on board data storage is non-volatile so data will not be lost in the event of a depleted battery. The Track-It™ DC Voltage and Current Loggers can also be used to record ambient temperature if one or neither input is being used. Information displayed on the LCD is also user programmable and can be sequenced by pressing the logger button. A multicolored LED indicator notifies the user of alarms, or general activity.
|
Features
- Push button to start recording immediately or program to start recording at a later time and date
- Up to 64,000 samples per recording session
- 500mVDC, 1VDC, 5VDC, 10VDC or 20mA
- +/- 0.5% accuracy
- Multiple alarm set points
- Compact size
- N.I.S.T. traceable calibration certificate available
- Integral USB interface/connector (no cable required)
- Powerful interactive Track-It Software package included
- 1 year or 5 year lithium battery options
- High accuracy and repeatability
- Accurate internal clock (1 minute/year)
Typical Uses
- Industrial process monitoring
- Trouble shooting problematic signals
- Productivity monitoring
- Remote indication
Track-It Software 
Track-It™ Software is a powerful Windows based software package that is included with every Track-It™ Data Logger. It allows for easy setup, retrieval, interpretation and export of the recorded data.Simply connect your Track-It™ data logger to an open USB port and begin communicating immediately.
Point and click to select your sample interval, alarm set points, engineering units, start recording triggers and LCD Displays.
View a numerical data table or graphical representation of data readings relative to time. Use the graph tools such as zoom, cursor, min and max to examine and analyze the record. Track-It™ Software turns your PC into a real time data acquisition system by allowing you to stream graphical or tabular data directly to your PC (capability varies by model). Use the one click export function to automatically export stored data into an Excel spreadsheet.
Compatible with Win XP/Vista/7, 32 and 64 Bit
|
Specifications
General
|
Record:
|
Sample Rates: User configured 1 every 2 seconds to 1 every 24 hours
No. of Samples: 32,000 or 64,000 (depends on config)
|
|
Record Trigger:
|
Two independent triggers. Multiple trigger modes:
Instantaneous, button control, on alarm, time and date (start and stop), day of week
|
|
Record Mode:
|
Fill to end of memory, cyclic, number of samples, time duration
|
|
Display:
|
4 digit LCD (Non display versions available with LED only)
User programmable: Indication of data value, eng units, alarms, record mode, battery condition, time/date, memory
|
|
LED:
|
User programmable: Indication of alarms, recording, triggered
|
|
Button:
|
User programmable: View display, record on/off, reset alarms, reset timer
|
|
Alarms:
|
2 user programmable alarms. High or Low
|
|
Communication:
|
Direct USB connection
|
|
Software:
|
Track-It™ Software—Program device, view data (historic or real time), export to Excel™. Simple and advanced modes
|
|
Battery:
|
Coin Cell Option: Battery: Lithium CR2032
Life: 1 year @ 1 minute sample rate
Hi Energy Option: Battery: EF651625
Life: 3 years @ 1 minute sample rate
|
|
Dimensions:
|
4.06” (10.32cm)L x 0.66” (1.67cm)H x 1.00” (2.54cm)W
|
Measurement
|
Temperature Range:
|
-20 to +85°C /-4 to 185°F w/EF65162 battery
-20 to +70°C /-4 to 158°F w/CR2032 battery
|
|
Accuracy:
|
±1°C 0 to 50°C / 32 to 122°F
±2°C –20 to 85°C / -4 to 185°F
|
|
Resolution:
|
0.1°C / 0.1°F
|
|
Clock
Accuracy:
|
±1 minute/year
|
Available Analog Modules (for DC V/I)
|
Range:
|
0 to 500mV (no preconditioning)
|
|
Accuracy:
|
±0.5% of full scale
|
|
Resolution:
|
±0.1mV
|
|
Input Modules
|
500mV, 1V, 5V, 10V, 20mA
|
|
Ordering Information
Note: The Track-It DC voltage and current modules can be ordered separately and used with Track-It Temp or Track-It RH/Temp data loggers or ordered as complete data loggers below. DC voltage and current modules are interchangeable.
| ITEM NUMBER |
MODEL |
DESCRIPTION |
|
| 5396-0511 |
Analog 500mV Track-It |
Logger with display, 500mV DC module and standard battery. Includes Track-It Software CD |
 |
| 5396-0512 |
Analog 1V Track-It |
Logger with display, 1V DC module and standard battery. Includes Track-It Software CD |
 |
| 5396-0513 |
Analog 5V Track-It |
Logger with display, 5V DC module and standard battery. Includes Track-It Software CD |
 |
| 5396-0514 |
Analog 10V Track-It |
Logger with display, 10V DC module and standard battery. Includes Track-It Software CD |
 |
| 5396-0515 |
Analog 20mA Track-It |
Logger with display, 20mA DC module and standard battery. Includes Track-It Software CD |
 |
| 5396-0521 |
Analog 500mV Track-It LB |
Logger with display, 500mV DC module and long life battery. Includes Track-It Software CD |
 |
| 5396-0522 |
Analog 1V Track-It LB |
Logger with display, 1V DC module and long life battery. Includes Track-It Software CD |
 |
| 5396-0523 |
Analog 5V Track-It LB |
Logger with display, 5V DC module and long life battery. Includes Track-It Software CD |
 |
| 5396-0524 |
Analog 10V Track-It LB |
Logger with display, 10V DC module and long life battery. Includes Track-It Software CD |
 |
| 5396-0525 |
Analog 20mA Track-It LB |
Logger with display, 20mA DC module and long life battery. Includes Track-It Software CD |
 |
| 5396-05-CAL |
NIST Analog |
N.I.S.T. traceable calibration certificate for logger/module combinations (above) |
 |
| 5396-0501 |
Analog 500mV Track-It module |
500mV DC Track-It Module (does not include logger) |
 |
| 5396-0502 |
Analog 1V Track-It module |
1V DC Track-It Module (does not include logger) |
 |
| 5396-0503 |
Analog 5V Track-It module |
5V DC Track-It Module (does not include logger) |
 |
| 5396-0504 |
Analog 10V Track-It module |
10V DC Track-It Module (does not include logger) |
 |
| 5396-0505 |
Analog 20mA Track-It module |
20mA Track-It Module (does not include logger) |
 |
|
|
|